Spectral imaging of the Orion Bar at 3.3, 8.4, and 11.3 microns: Comparison with a fluorescent polycyclic aromatic hydrocarbon model

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

23

Astronomical Models, Emission Spectra, Interstellar Matter, Orion Nebula, Line Spectra, Size Distribution, Spectral Bands

Scientific paper

Spectral images were obtained of the Orion Bar which sample polycyclic aromatic hydrocarbon (PAH) emission at 3.3, 8.4, and 11.3 micrometers. The images are strikingly different even though they all sample PAH emission. In particular, the 3.3 and 11.3 micrometers images sample PAH emission from C-H bonds, yet the 3.3 micrometers image contains many small bright knots while the 11.3 micrometers image is much more uniform. For comparison with a fluorescent PAH model, a data set was created from the measured intensities of 250 locations in each image. From the comparison, we conclude that: (1) the size distribution of PAHs varies within the Bar, with the bright 3.3 micrometers knots containing the largest proportion of small PAHs; (2) the points along the front of the Bar have emission cross sections characteristic of neutral PAHs while within the Bar, the emission cross sections are different, consistent with the PAHs being charged; (3) the PAHs along the front of the Bar are larger than average for the Bar; (4) emission along the back of the Bar is consistent with PAH emission in an attenuated UV radiation field; (5) there is no evidence for PAH dehydrogenation.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Spectral imaging of the Orion Bar at 3.3, 8.4, and 11.3 microns: Comparison with a fluorescent polycyclic aromatic hydrocarbon model does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Spectral imaging of the Orion Bar at 3.3, 8.4, and 11.3 microns: Comparison with a fluorescent polycyclic aromatic hydrocarbon model, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Spectral imaging of the Orion Bar at 3.3, 8.4, and 11.3 microns: Comparison with a fluorescent polycyclic aromatic hydrocarbon model will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1870547

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.