Presented at the 8th International Cryocooler Conference, Vail, CO, 28-30 Jun. 1994
Other
Aerospace Environments, Cooling, Focal Plane Devices, Ground Tests, Imaging Techniques, Infrared Detectors, Infrared Radiation, Mercury Cadmium Tellurides, Stirling Cycle, Controllers, Coolers, Diodes, Lunar Maps, Lunar Surface, Operating Temperature, Spectral Bands, Temperature Control, Thermal Environments
Scientific paper
Two Ricor K506B Stirling cycle cryocoolers with H-10 control electronics were used on the Clementine spacecraft, one cooling a 256 x 256 InSb infrared detector for the near-infrared (NIR) camera and the other cooling a 128 x 128 HgCdTe focal plane array on the longwave infrared (LWIR) camera. This is the first use of these Ricor Stirling cryocoolers in a space environment. This mission has demonstrated the use of these Clementine lightweight imaging sensors in the demanding environment of space, and has space-qualified this Ricor cryocooler. Moreover, nearly the entire 38 million square kilometers of the Moon's surface was mapped in 11 spectral bands, six in the near-infrared, during the 71 days of lunar mapping. The more than 1.6 million digital images collected are providing-mineral typing scientific data to the international civilian scientific community. The NIR cryocooler operated successfully for a total of 840 hours with 361 on/off cycles. The H-10 electronics provided good focal plane array (FPA) temperature control with a typical operating FPA temperature of 70.3 K and a one-sigma variation of 0.46 K. The thermal environment for the cooler ranged from -23.7 C to 38.2 C. The Ricor cryocooler used on the LWIR camera performed the same during the Clementine mission as it did on the ground. This cryocooler ran for a total of 670 hours with 359 on/off cycles. The H-10 electronics were not able to provide FPA temperature control. This inability to operate at a fixed set point is believed to be caused by a ground difference between the H-10 controller electronics and the FPA temperature sense diode. The FPA temperature varied in proportion to the cryocooler (heat reject) temperature. The FPA temperature during imaging varied from 66.9 K to greater than 85 K. The thermal environment for this cooler ranged from -22.1 C to 41.0 C.
Clark Thomas L.
Hadley Dean R.
Priest Robert E.
Robinson Jeffrey A.
Sewall Noel R.
No associations
LandOfFree
Ricor K506B cryocooler performance during the Clementine mission and ground testing does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Ricor K506B cryocooler performance during the Clementine mission and ground testing, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Ricor K506B cryocooler performance during the Clementine mission and ground testing will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1713787