Astronomy and Astrophysics – Astronomy
Scientific paper
Sep 2006
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2006pabei..24..277z&link_type=abstract
Progress in Astronomy (ISSN 1000-8349), Vol. 24, No. 3, p. 277 - 284 (2006)
Astronomy and Astrophysics
Astronomy
Astronomical Facilities And Technique, Cesium Beam Frequency Standard, Cosine Fourier Transform, Second-Order Doppler Frequency Shift, Optical Pumping
Scientific paper
In this paper, it is demonstrated that the Cosine Fourier transform method is effective at researching the distribution of atomic velocity. Then we have analyzed the Ramsey pattern in our optically pumped cesium beam frequency standard and obtained the velocity distribution of cesium atom. This distribution accords with the theoretical construction of the cesium beam tube. The Second-order Doppler frequency shift is calculated accurately by the known velocity distribution and the resulting overall accuracy of the standard is estimated to be -3.5×10-13.
No associations
LandOfFree
Researching of the second-order Doppler frequency shift in optically pumped cesium frequency standard does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Researching of the second-order Doppler frequency shift in optically pumped cesium frequency standard, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Researching of the second-order Doppler frequency shift in optically pumped cesium frequency standard will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-960580