4

Absorption, Instrument Compensation, Paraboloid Mirrors, Reflectance, Synchrotron Radiation, X Ray Astrophysics Facility, Edges, Light Sources, Metal Coatings, Metal Films

Scientific paper

We are developing a system to calibrate reflectances of witness coupons to the AXAF flight mirrors at the National Synchrotron Light Source over the 0.05-12 keV energy range. These witness coupons will be coated in the same process as the AXAF mirror elements. One of the key issues is the accurate determination of mirror efficiencies across the absorption edges of the mirror coating elements. We present a series of reflectance measurements with 2 eV resolution of a nickel-coated flat mirror in the region of the Ni L-II (870 eV) and L-III (853 eV) absorption edges. Scans of reflectance versus grazing angle at fixed energies in this region show distinct interference fringes at grazing angles larger than the critical angle which are extinguished as the photon energy is increased beyond the low point of the L-III edge, indicating total absorption of the evanescent wave within the Ni film. At 51 arc minutes grazing angle, measured reflectance decreases smoothly by 35 percent and then recovers in an 8 eV band at the L-III edge. We have also measured reflectances in the M absorption edge region for gold, platinum, and iridium coated mirrors. We derive optical parameters n and k specific to the film for comparison to the existing data tables.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1265319

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.