Seismic broad-band sensors are known to be sensitive to the magnetic field. Magnetic storms and man-made disturbances of the magnetic field can produce significant noise in seismic recordings. I show that variations in the magnetic field translate directly into apparent acceleration of the seismic sensor within the period range from 60 to 1200s for all leaf-spring sensors under investigation. For a Streckeisen STS-1V this is shown even for periods down to 1s. The sensitivity is quantified in magnitude and direction. Both are quite stable over many time windows and signal periods. The sensitivities obtained by linear regression of the acceleration signal on magnetic field recordings during a magnetic storm can effectively be applied to reduce noise in seismic signals. The sensitivity varies in magnitude from sensor to sensor but all are in the range from 0.05 to 1.2ms-2T-1. Seismograms from sensors at Black Forest Observatory (BFO) and stations of the German Regional Seismic Network were investigated. Although these are mainly equipped with leaf-spring sensors, the problem is not limited to this type of instrument. The effect is not observable on the horizontal component STS-1s at BFO while it is significant in the recordings of the vertical STS-1. The main difference between these instruments is the leaf-spring suspension in the vertical component that appears to be the source of the trouble. The suspension springs are made of temperature compensated Elinvar alloys that inherently are ferromagnetic and may respond to the magnetic field in various ways. However, the LaCoste Romberg ET-19 gravimeter at BFO, which uses this material too, does not respond to magnetic storms at a similar magnitude neither do the Invar-wire strainmeters. An active shielding, composed of three Helmholtz coils and a feedback system, is installed at station Stuttgart and provides an improvement of signal-to-noise ratio by almost a factor of 20 at this particular station. The passive Permalloy shielding commonly installed with STS-1V sensors performs similarly well.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Reducing magnetic field induced noise in broad-band seismic recordings does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Reducing magnetic field induced noise in broad-band seismic recordings, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Reducing magnetic field induced noise in broad-band seismic recordings will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1080287

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.