Infrared projection systems based on resistor arrays typically produce radiometric outputs with wavelengths that range from less than 3 microns to more than 12 microns. This makes it possible to test infrared sensors with spectral responsivity anywhere in this range. Two resistor-array projectors optically folded together can stimulate the two bands of a 2-color sensor. If the wavebands of the sensor are separated well enough, it is possible to fold the projected images together with a dichroic beam combiner (perhaps also using spectral filters in front of each resistor array) so that each resistor array independently stimulates one band of the sensor. If the wavebands are independently stimulated, it is simple to perform radiometric calibrations of both projector wavebands. In some sensors, the wavebands are strongly overlapping, and driving one of the resistor arrays stimulates both bands of the unit-under-test (UUT). This "coupling" of the two bands causes errors in the radiance levels measured by the sensor, if the projector bands are calibrated one at a time. If the coupling between the bands is known, it is possible to preprocess the driving images to effectively decouple the bands. This requires performing transformations, which read both driving images (one in each of the two bands) and judiciously adjusting both projectors to give the desired radiance in both bands. With this transformation included, the projection system acts as if the bands were decoupled varying one input radiance at a time only produces a change in the corresponding band of the sensor. This paper describes techniques that have been developed to perform radiometric calibrations of spectrally coupled, 2-color projector/sensor systems. Also presented in the paper are results of tests performed to demonstrate the performance of the calibration techniques. Possible hardware and algorithms for performing the transformation in real-time are also presented.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Radiometrically calibrating spectrally coupled two-color projectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Radiometrically calibrating spectrally coupled two-color projectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Radiometrically calibrating spectrally coupled two-color projectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1089804

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.