Many future space missions will use cadmium zinc telluride (CdZnTe) gamma-ray detectors because their operation at room temperature makes compact, lightweight detector systems possible. Even though instruments for space using CdZnTe detectors have already been built, the effect of the high- energy particle space environment on these detectors has not been measured. To determine the effect of energetic charged particles on these detectors, we have bombarded several CdZnTe detectors with 199 MeV protons at the Indianan University Cyclotron Facility. Planar detectors of area 1 cm(superscript 2) and thickness 2-3 mm from both eV products and Digirad were irradiated, along with a 2 multiplied by 2 array of proprietary design from Digirad. Using standard gamma-ray sources, the response of the detectors was measured before and after bombardment in steps up to fluences of 5 multiplied by 10(superscript 9) p cm(superscript -2). Significant effects from the proton irradiation were observed in the gamma-ray spectra. In particular, the peak positions of the lines in the spectrum were shifted downward proportional to the fluence. The explanation is almost certainly the production of electron traps by the high energy proton interactions, resulting in a decrease of the mobility-lifetime ((mu) (tau) ) product of the electrons. Calculations were made to model the effect of a decrease in electron trapping length on the spectrum.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Radiation effects in CdZnTe gamma-ray detectors produced by 199-MeV protons does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Radiation effects in CdZnTe gamma-ray detectors produced by 199-MeV protons, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Radiation effects in CdZnTe gamma-ray detectors produced by 199-MeV protons will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1141491

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.