Statistics – Applications
Scientific paper
Jan 2002
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2002aipc..608...37k&link_type=abstract
SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM- STAIF 2002. Conference on Thermophyiscs in Microgravity; Conference on In
Statistics
Applications
Flows In Ducts, Channels, Nozzles, And Conduits, Spaceborne And Space Research Instruments, Apparatus, And Components, Heat Engines, Heat Pumps, Heat Pipes, Heat Flow In Multiphase Systems
Scientific paper
This paper describes the design and fabrication of a propylene Loop Heat Pipe (LHP) with a flexible, deployable radiator intended to provide a lightweight spacecraft thermal management system. The paper presents the results of testing the LHP in an environmental chamber and in a thermal-vacuum chamber. Observations regarding operational and startup characteristics of the LHP are provided, and a comparison of design calculations to test results is presented. .
Crowley Christopher J.
Krotiuk William J.
Rozzi Jay C.
No associations
LandOfFree
Propylene loop heat pipe with a lightweight, flexible, deployable radiator does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Propylene loop heat pipe with a lightweight, flexible, deployable radiator, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Propylene loop heat pipe with a lightweight, flexible, deployable radiator will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1086240