Precise calibration of LIGO test mass actuators using photon radiation pressure

Astronomy and Astrophysics – Astrophysics – General Relativity and Quantum Cosmology

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

13 pages, 6 figures, accepted by Classical and Quantum Gravity

Scientific paper

10.1088/0264-9381/26/24/245011

Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a so-called photon calibrator, has been demonstrated previously and has recently been implemented on the LIGO detectors. In this article, we discuss the inherent precision and accuracy of the LIGO photon calibrators and several improvements that have been developed to reduce the estimated voice coil actuator calibration uncertainties to less than 2 percent (1-sigma). These improvements include accounting for rotation-induced apparent length variations caused by interferometer and photon calibrator beam centering offsets, absolute laser power measurement using temperature-controlled InGaAs photodetectors mounted on integrating spheres and calibrated by NIST, minimizing errors induced by localized elastic deformation of the mirror surface by using a two-beam configuration with the photon calibrator beams symmetrically displaced about the center of the optic, and simultaneously actuating the test mass with voice coil actuators and the photon calibrator to minimize fluctuations caused by the changing interferometer response. The photon calibrator is able to operate in the most sensitive interferometer configuration, and is expected to become a primary calibration method for future gravitational wave searches.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Precise calibration of LIGO test mass actuators using photon radiation pressure does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Precise calibration of LIGO test mass actuators using photon radiation pressure, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Precise calibration of LIGO test mass actuators using photon radiation pressure will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-404665

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.