Performance Test for a PDS Microdensitometer Model 1010GMS

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The electrical, mechanical and optical capabilities have been tested of the microdensitometer PDS 1010GMS at the Korea Astronomy Observatory. The highest stage of scan speed 255 csu (conventional speed unit) is measured to be 47 mm/sec. At this speed the position is displaced by 4 micrometer to the direction of scanning and the density is underestimated by 0.4-0.7D. Standard deviation in the measured density is proportional to A^-0.46 where A is the area of scan aperture. The accuracy of position repeatability is +-1 micrometer, and that of density repeatability is +- 0.003-0.03D. Callier coefficient is determined to be 1.37; the semispecular density is directly proportional to the diffuse density up to 3.5D. Because the logarithmic amplifier has a finite response time, the densities measured at high scan speeds are underestimated to the degree that speeds higher than 200 csu are inadequate for making an accurate astronomical photometry. After power is on, an about 5 hour period of warming is required to stabilize the system electrically and mechanically as well. On the basis of this performance test, we have determined the followings as the optimum scan parameters for the astronomical photometry: For the scan aperture 10-20 micrometer is optimal, and for the scan speed 20-50 csu is appropriate. These parameter values are chosen in such a way that they may keep the density repeatability within +- 0.1D, the position displacement under 1 micrometer, and the density underestimation below 0.1D even in high density regions.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Performance Test for a PDS Microdensitometer Model 1010GMS does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Performance Test for a PDS Microdensitometer Model 1010GMS, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Performance Test for a PDS Microdensitometer Model 1010GMS will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1207458

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.