Scientific paper
A five-segment n-type coacial detector with associated test cryostat and electronics has been fabricated and tested. Measurements were made of detector efficiency as a function of the number of segments in which interactions occur and the energy threshold of the segment discriminators. The performance of the detector agrees well with predictions. A second detector is now being fabricated along with a rugged mount, flight cryostat, and electronics for use in a future balloon flight.
Cork Chris P.
Landis Don A.
Ling James C.
Luke Paul N.
Madden Norman W.
No associations
LandOfFree
Performance of a five-segment coacial n-type germanium detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Performance of a five-segment coacial n-type germanium detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Performance of a five-segment coacial n-type germanium detector will most certainly appreciate the feedback.