Optimization of X-ray absorbers for TES microcalorimeters

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Scientific paper

We have investigated the thermal, electrical, and structural properties of Bi and BiCu films that are being developed as X-ray absorbers for transition-edge sensor (TES) microcalorimeter arrays for imaging X-ray spectroscopy. Bi could be an ideal material for an X-ray absorber due to its high X-ray stopping power and low specific heat capacity, but it has a low thermal conductivity, which can result in position dependence of the pulses in the absorber. In order to improve the thermal conductivity, we added Cu layers in between the Bi layers. We measured electrical and thermal conductivities of the films around 0.1 K, the operating temperature of the TES calorimeter, to examine the films and to determine the optimal thickness of the Cu layer. From the electrical conductivity measurements, we found that the Cu is more resistive on the Bi than on a Si substrate. Together with a SEM picture of the Bi surface, we concluded that the rough surface of the Bi film makes the Cu layer resistive when the Cu layer is not thick enough to fill in the roughness. From the thermal conductivity measurements, we determined the thermal diffusion constant to be 2 x 103 µm2µs-1 in a film that consists of 2.25 µm of Bi and 0.1 µm of Cu. We measured the position dependence in the film and found that its thermal diffusion constant is too low to get good energy resolution, because of the resistive Cu layer and/or possibly a very high heat capacity of our Bi films. We show plans to improve the thermal diffusion constant in our BiCu absorber.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Optimization of X-ray absorbers for TES microcalorimeters does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Optimization of X-ray absorbers for TES microcalorimeters, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Optimization of X-ray absorbers for TES microcalorimeters will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1823189

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.