Astronomy and Astrophysics – Astronomy
Scientific paper
Mar 1998
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1998balta...7..341k&link_type=abstract
Baltic Astronomy, v.7, p.341-348.
Astronomy and Astrophysics
Astronomy
1
Instrumentation: Photometers
Scientific paper
The temperature dependence of spectral sensitivity of the Hamamatsu photomultipliers R 647P and R 1463P is investigated in the temperature interval --5 (--15) deg to +25 deg for the wavelength range between 280 and 820 (850) nm. The influence of the temperature variations on spectral sensitivity of PMTs and transmittance of the {UBV} filters to the accuracy of the WET and classical UBV photometry is estimated. It is argued that the temperature effects should be taken into account in WET observations as in the case of precise UBV photometry.
Kalytis R.
Meištas E. G.
Sperauskas Julius
No associations
LandOfFree
On the Necessity to Standardize Photometric Parameters of the Wet Photometers does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with On the Necessity to Standardize Photometric Parameters of the Wet Photometers, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and On the Necessity to Standardize Photometric Parameters of the Wet Photometers will most certainly appreciate the feedback.