Novel high-resolution readout for UV and x-ray photon counting detectors with microchannel plates

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Until recently the spatial resolution of microchannel plate based photon/particle counting sensors has generally been limited by the accuracy of the readout technique. The accuracy of novel readouts, in particular cross strip anodes, have now reached the 6-10μm scale (the typical size of pores in a microchannel plate) and no longer determine the ultimate resolution limit of the detector. Although there are some issues (e.g. fixed pattern distortions seen on 5 μm scale) to be resolved for the cross strip (XS) anodes, one of the major drawbacks of the previous generation XS readouts is the low counting rate capability (10 KHz), determined by the processing electronics, in particular by the signal amplifier ASICs. In this paper we describe a new signal processing technique which should allow for high counting rates exceeding 1 MHz with the same high spatial resolution (<10 μm FWHM). The slow analog sample and hold signal processing is replaced by a fully parallel signal amplification followed by digital peak detection in each output channel. The charge values in each electrode are calculated from the digitized waveforms passed into a Field Programmable Gate Array (FPGA) where the signal peak detection and event centroiding is performed continuously. A detailed model was developed in order to optimize the digital peak detection algorithms and to determine the acceptable parameters for the electronic elements for a given spatial resolution. The results of our Monte Carlo modeling indicate that the spatial resolution of fast XS anode encoding electronics will still be better than 10 μm FWHM.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Novel high-resolution readout for UV and x-ray photon counting detectors with microchannel plates does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Novel high-resolution readout for UV and x-ray photon counting detectors with microchannel plates, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Novel high-resolution readout for UV and x-ray photon counting detectors with microchannel plates will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1894090

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.