Computer Science – Sound
Scientific paper
Dec 1978
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1978georl...5.1023h&link_type=abstract
Geophysical Research Letters, vol. 5, Dec. 1978, p. 1023-1026.
Computer Science
Sound
Air Sampling, Chemiluminescence, Gas Detectors, Nitric Oxide, Rocket-Borne Instruments, Stratosphere, Error Analysis, Instrument Errors, Mass Ratios, Ozone, Photomultiplier Tubes, Rocket Sounding
Scientific paper
The nitric oxide mixing ratio between 43 km and 61 km was directly measured with a rocket-borne chemiluminescent detector. The ozone-generated background signal was monitored throughout the flight (in 1976) by periodically interrupting the atmospheric sample flow with a pure-N2 bias-supply gas. An error analysis of the 1976 results showed the need to correct results obtained from an earlier flight (in 1975). The corrected 1975 results are reported and compared with the 1976 results.
Horvath Jorge
Mason C. J.
No associations
LandOfFree
Nitric oxide mixing ratios near the stratopause measured by a rocket-borne chemiluminescent detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Nitric oxide mixing ratios near the stratopause measured by a rocket-borne chemiluminescent detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Nitric oxide mixing ratios near the stratopause measured by a rocket-borne chemiluminescent detector will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-887514