NIST facility for spectral calibration of detectors: calibration of arsenic-doped silicon-blocked impurity band detectors

Statistics – Methodology

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The capability of the Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology to spectrally calibrate infrared detectors was demonstrated with the spectral calibration of arsenic doped silicon blocked impurity band (BIB) detectors. The BIB detectors were calibrated over the 2 micrometer to 30 micrometer range, using light from a monochromator with a nominal 2% bandwidth. Photon fluxes used for the calibration ranged from 1013 photons/s/cm2 to 1014 photons/s/cm2. The large area detectors (10 mm2) calibrated in this paper were very linear up to 2.5 X 1014 photons/s/cm2, where they showed a 1% drop in signal from linearity. The calibrations contained less than 6 1% standard component of random noise uncertainty, and there was about a 6 5% standard component of uncertainty arising from systemic effects that will be discussed in detail. The calibrations were performed in ultra- high vacuum in a 20 K background environment by making direct intercomparisons between the power measured by an absolute cryogenic radiometer and the response measured by a detector irradiated by the same beam. A detailed description of measurement methodology and system apparatus is given. Detector linearity and uniformity are also discussed. The LBIR facility can now provide calibrated BIB detectors as transfer standards as well as evaluate and calibrate customer's large area detectors and detector arrays provided the detectors stay within certain physical limitations.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

NIST facility for spectral calibration of detectors: calibration of arsenic-doped silicon-blocked impurity band detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with NIST facility for spectral calibration of detectors: calibration of arsenic-doped silicon-blocked impurity band detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and NIST facility for spectral calibration of detectors: calibration of arsenic-doped silicon-blocked impurity band detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1484028

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.