Nanoscale porosity in SAFOD core samples (San Andreas Fault)

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

5

Scientific paper

With transmission electron microscopy (TEM) we observed nanometer-sized pores in four ultracataclastic and fractured core samples recovered from different depths of the main bore hole of the San Andreas Fault Observatory at Depth (SAFOD). Cutting of foils with a focused ion beam technique (FIB) allowed identifying porosity down to the nm scale. Between 40 and 50% of all pores could be identified as in-situ pores without any damage related to sample preparation. The total porosity estimated from TEM micrographs (1-5%) is comparable to the connected fault rock porosity (2.8-6.7%) estimated by pressure-induced injection of mercury. Permeability estimates for cataclastic fault rocks are 10- 21-10- 19 m2 and 10- 17 m2 for the fractured fault rock. Porosity and permeability are independent of sample depth. TEM images reveal that the porosity is intimately linked to fault rock composition and associated with deformation. The TEM-estimated porosity of the samples increases with increasing clay content. The highest porosity was estimated in the vicinity of an active fault trace. The largest pores with an equivalent radius > 200 nm occur around large quartz and feldspar grains or grain-fragments while the smallest pores (equivalent radius < 50 nm) are typically observed in the extremely fine-grained matrix (grain size < 1 μm). Based on pore morphology we distinguish different pore types varying with fault rock fabric and alteration. The pores were probably filled with formation water and/or hydrothermal fluids at elevated pore fluid pressure, preventing pore collapse. The pore geometry derived from TEM observations and BET (Brunauer, Emmett and Teller) gas adsorption/desorption hysteresis curves indicates pore blocking effects in the fine-grained matrix. Observations of isolated pores in TEM micrographs and high pore body to pore throat ratios inferred from mercury injection suggest elevated pore fluid pressure in the low permeability cataclasites, reducing shear strength of the fault.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Nanoscale porosity in SAFOD core samples (San Andreas Fault) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Nanoscale porosity in SAFOD core samples (San Andreas Fault), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Nanoscale porosity in SAFOD core samples (San Andreas Fault) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1593226

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.