Monitoring and analysis of anomalous refraction using a digital zenith camera system

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4

Astrometry

Scientific paper

Context: .Anomalous refraction is considered to be a limiting factor for ground-based astrometry in general and astrogeodetic observations in particular. Typical characteristics of anomalous refraction are basically known by means of spot-check-data, however the fluctuation is rather little studied. Aims: .The goal of this study is to derive empirical knowledge on the fluctuation of anomalous refraction in the optical domain. Methods: .A Digital Zenith Camera System usually applied for the astrogeodetic determination of the Earth's gravity field has been used for continuously monitoring anomalous refraction. With a sample frequency of about 2 observations per minute, about 7300 single observation epochs were collected during 6 nights. Residuals of the observations with respect to reference data show how anomalous refraction behaves. Results: .The analysis of approximately 70 h of observational data reveals heterogeneous fluctuation patterns of anomalous refraction at the zenith. Wave-like and bump-like variations appear as well as slowly-changing, drift-like structures. With respect to its magnitude, the effect reaches from 0.05 arcsec up to about 0.2 arcsec at frequencies of some hours. Even much lower frequencies of anomalous refraction are indicated in the data sets causing an offset of about 0.04 arcsec. The accuracy of the filtered data has been found to be about 0.05 arcsec-0.08 arcsec. Conclusions: .The study indicates how anomalous refraction may fluctuate. The results are considered to give an estimate of the accuracy limit for astrogeodetic and other absolute ground-based astrometric observations.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Monitoring and analysis of anomalous refraction using a digital zenith camera system does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Monitoring and analysis of anomalous refraction using a digital zenith camera system, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Monitoring and analysis of anomalous refraction using a digital zenith camera system will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1309923

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.