Molecular lines as tracers of Compton-thick AGN ?

Astronomy and Astrophysics – Astrophysics – Cosmology and Extragalactic Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

To appear in A&A Letters

Scientific paper

Recently, Papadopoulos et al., 2010 using sub-mm CO molecular line observations of nearby ultra-luminous IRAS galaxies, (U)LIRGs, have found that exceptionally large gas column densities (N_H > 10^25 cm-2) can be present across some of the very dense gaseous disks that are typically found in these objects. They also proposed a diagnostic for finding such sources using CO and HCN molecular lines. Given that such high column densities are expected to absorb any X-ray luminous AGN, yielding Compton-thick sources, we set out toexplore whether this can be discerned using X-ray observations. More specifically we examine X-ray spectral observations of 14 sources in their sample, using public Chandra observations (0.5-10 keV) for eleven sources as well as BeppoSAX results (2-100 keV) from the literature for another three sources. Our goal is to find candidate Compton-thick AGN and to check whether the molecular line selection criterion is successful in selecting such systems. X-ray spectroscopy reveals four candidate Compton-thick AGN of which half fall within the high obscuration region in the molecular line ratio diagnostics. Of the remaining five sources falling into the `high dust obscuration' box, one (Mrk273) is highly obscured (N_H ~4x10^23 cm-2) while in the other four the X-ray emission is most probably associated with star-forming processes rather than an AGN on the basis of their X-ray and mid-infrared properties. Overall, we argue that although this method as expected cannot recover all Compton-thick AGN, there are no examples of X-ray luminous AGN inside that region that have low obscuration, suggesting that this method is efficient in finding heavily obscured AGN in dust-enshrouded star-forming galaxies. The above results bear important implications for future joint ALMA and X-ray observations for the detection of Compton-thick AGN.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Molecular lines as tracers of Compton-thick AGN ? does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Molecular lines as tracers of Compton-thick AGN ?, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Molecular lines as tracers of Compton-thick AGN ? will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-684846

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.