Microsecond pulsed glow discharge source in ``Element GD'' and ``VG 9000'' mass-spectrometers

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Microsecond pulsed glow discharge (PGD) may consume several kW of instantaneous power that may lead to a significant increase of a sample atoms excitation and ionization efficiency. Improvement of analytical characteristics of a glow discharge source using pulsed mode of power supply is demonstrated earlier for different optical and mass spectral methods (Drobyshev, Turkin 1981, Bengtson et al. 2000, Huang et al. 1991, Hang et al. 1996, 1994, Farnsworth, Walters 1982), including fast flow ion source (Voronov, Hoffmann 2007). However, practical use of microsecond PGD is limited to scientific investigations.
In this work the microsecond PGD is applied to existing commercial mass-spectrometers ``Element GD'' and ``VG 9000'' to develop a system, which can be used in commercial routine analysis. Investigations are focused on possibilities of analysis with microsecond PGD and in comparison of PGD in fast flow source (``Element GD'') and usual Grimm type source (``VG 9000''). Detection limits in DC and PGD modes are investigated and compared.
The secondary discharge in Grimm type fast flow source was discovered in (Voronov, Hoffmann 2007), and it certainly exists in ``Element GD'' instrument. However, practical application of the secondary discharge for improvement of analytical properties of the instrument is not clear. To answer this question, dynamics of ions extracted from the discharge pulses is measured using earlier developed method (Voronov, Hoffmann 2007) (see the fig.). Based on the measured ion dynamics and results of the PGD numerical simulation, influence of the secondary discharge in ``Element GD'' instrument is discussed.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Microsecond pulsed glow discharge source in ``Element GD'' and ``VG 9000'' mass-spectrometers does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Microsecond pulsed glow discharge source in ``Element GD'' and ``VG 9000'' mass-spectrometers, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Microsecond pulsed glow discharge source in ``Element GD'' and ``VG 9000'' mass-spectrometers will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-788170

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.