Measuring the X-ray transmission function of the ACIS UV/Optical blocking filters at the National Synchrotron Light Source.

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The 0.26 to 3 keV X-ray transmission of the AXAF/ACIS UV/Optical blocking filters was measured at the National Synchrotron Light Source (NSLS) at Brookhaven. The main objective of the calibration was to determine an X-ray transmission function with an uncertainty of less than 1%. The ACIS UV/Optical Imager and Spectrometer blocking filters consist of LEXAN,a polycarbonate plastic with a chemical composition of C16H14O3, with a layer of aluminum coated on each side to provide optical light blocking. The X-ray transmission data can not be well fitted, especially at fine energy scales, with models that incorporate Henke absorption coefficients alone. Residuals between the X-ray transmission data and models that utilize the Henke absorption coefficients are as high as 50% and are mostly due to extended X-ray absorption fine structure (EXAFS) that appears above the C, O and Al absorption edges. We provide an analytic expression for the transmission function of the ACIS UV/Optical blocking filters which combines an X-ray transmission derived from Henke mass attenuation coefficients with a component to characterize the EXAFS contribution. EXAFS theory predicts a temperature dependence on the amplitude of the EXAFS oscillations. This dependence arises from the fact that thermal vibrations of the atoms in a solid produce a phase mismatch of the backscattered electron wave function. We derive a simple expression to predict the on-orbit X-ray transmission from the X-ray transmission measured on ground. Finally we present several examples where the presence of EXAFS in the X-ray transmission of a filter may significantly influence the interpretation of spectral data originating from celestial X-ray sources.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measuring the X-ray transmission function of the ACIS UV/Optical blocking filters at the National Synchrotron Light Source. does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measuring the X-ray transmission function of the ACIS UV/Optical blocking filters at the National Synchrotron Light Source., we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measuring the X-ray transmission function of the ACIS UV/Optical blocking filters at the National Synchrotron Light Source. will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1354360

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.