Measuring remanence anisotropy of hematite in red beds: anisotropy of high-field isothermal remanence magnetization (hf-AIR)

Mathematics – Logic

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

5

Magnetic Fabrics And Anisotropy, Magnetic Mineralogy And Petrology, Paleomagnetism Applied To Geologic Processes

Scientific paper

The potential of using high-field anisotropy of isothermal remanence magnetization (hf-AIR) measurements for determining the origin of natural remanent magnetization in red beds and for identifying and correcting possible red-bed inclination shallowing was investigated for specimens of the Carboniferous Shepody Formation of New Brunswick and Nova Scotia, Canada. The technique makes it possible for a typical paleomagnetic laboratory to measure the remanence anisotropy of high-coercivity hematite.
High-field (hf) AIR was used in conjunction with 100 mT alternating field (af) and 120°C thermal demagnetization to separate the contribution of hematite to the remanence anisotropy from that of magnetite/maghemite and goethite, respectively. A 5-T impulse DC magnetic field was used for the hf-AIR to reset the magnetic moment of high-coercivity hematite so that demagnetization between AIR orientations was not necessary. The ability of a 5-T field to reset the magnetization was tested by generating an isothermal remanent magnetization acquisition curve for hematite by using impulse DC magnetic fields up to 5 T in one orientation and followed by applying a field in the opposite direction at each step. Each field application was treated by 120°C heating and 100 mT af demagnetization before measurement. At 5 T, the difference between the magnetizations applied in opposite directions disappeared indicating that no magnetic memory persisted at this field strength. We performed a validity and reproducibility test of our hf-AIR measurement technique by measuring three specimens multiple times along two orthogonal coordinate systems. The method yielded highly reproducible results and, on rotating the specimen's coordinates, the fabric rotated by 90° as expected, showing that it is not an artifact of the technique. We also measured hf-AIR on samples that had previously been chemically demagnetized in 3N HCl to remove the secondary, chemically grown pigmentary hematite. The hf-AIR fabric of leached samples is similar to that of untreated samples, but shows a better-defined magnetic lineation and imbrication. We interpret the fabric observed for the Shepody Formation to be a compactional fabric that has been reoriented by strain during folding following a flexural-slip model.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measuring remanence anisotropy of hematite in red beds: anisotropy of high-field isothermal remanence magnetization (hf-AIR) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measuring remanence anisotropy of hematite in red beds: anisotropy of high-field isothermal remanence magnetization (hf-AIR), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measuring remanence anisotropy of hematite in red beds: anisotropy of high-field isothermal remanence magnetization (hf-AIR) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1191273

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.