Measurement of the Relativistic Potential Difference Across a Rotating Dielectric Cylinder

Astronomy and Astrophysics – Astrophysics – General Relativity and Quantum Cosmology

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

22 pages, 5 figures; to be published in the American Journal of Physics

Scientific paper

10.1119/1.1362695

According to the Special Theory of Relativity, a rotating magnetic dielectric cylinder in an axial magnetic field should exhibit a contribution to the radial electric potential that is associated with the motion of the material's magnetic dipoles. In 1913 Wilson and Wilson reported a measurement of the potential difference across a magnetic dielectric constructed from wax and steel balls. Their measurement has long been regarded as a verification of this prediction. In 1995 Pelligrini and Swift questioned the theoretical basis of experiment. In particular, they pointed out that it is not obvious that a rotating medium may be treated as if each point in the medium is locally inertial. They calculated the effect in the rotating frame and predicted a potential different from both Wilson's theory and experiment. Subsequent analysis of the experiment suggests that Wilson's experiment does not distinguish between the two predictions due to the fact that their composite steel-wax cylinder is conductive in the regions of magnetization. We report measurements of the radial voltage difference across various rotating dielectric cylinders, including a homogeneous magnetic material (YIG), to unambiguously test the competing calculations. Our results are compatible with the traditional treatment of the effect using a co-moving locally inertial reference frame, and are incompatible with the predictions based on the model of Pelligrini and Swift.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measurement of the Relativistic Potential Difference Across a Rotating Dielectric Cylinder does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measurement of the Relativistic Potential Difference Across a Rotating Dielectric Cylinder, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement of the Relativistic Potential Difference Across a Rotating Dielectric Cylinder will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-287797

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.