Astronomy and Astrophysics – Astrophysics
Scientific paper
Mar 2011
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2011astra...7...79c&link_type=abstract
Astrophysics and Space Sciences Transactions, Volume 7, Issue 1, 2011, pp.79-83
Astronomy and Astrophysics
Astrophysics
Scientific paper
We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 ± 0.0032 (stat.) ± 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by underground experiments.
Calderón A.
CMS Collaboration
No associations
LandOfFree
Measurement of the charge ratio of atmospheric muons with the CMS detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Measurement of the charge ratio of atmospheric muons with the CMS detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement of the charge ratio of atmospheric muons with the CMS detector will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-861113