Measurement and modeling of the x-ray spectral response of bulk GaAs detectors

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

In light of recent developments in hard x-ray focusing, work has been carried out at the University of Leicester, to investigate the use of high-Z materials (principally GaAs) for detecting x-rays in the 10 to 100 keV regime. The x-ray astronomy group at Leicester has been involved with developing the detectors and optics for several instruments including the Rosat wide field camera, JET-X an XMM, but both the grazing incidence optics, and the quantum efficiency of more conventional detectors, e.g. silicon CCDs, have limited the energy response to less than 10 keV. Ge, CdTe, HgI and GaAs all offer higher quantum efficiency than silicon and are being investigated as a possible means to extending the energy response of future telescopes, aimed at studying non-thermal processes beyond the iron lines. Detectors have been fabricated using bulk and epitaxially grown GaAs and tested at a range of temperatures between minus 130 degrees Celsius and room temperature. The behavior of bulk GaAs detectors is dominated by carrier trapping leading to imperfect charge collection efficiency (CCE) and traditionally poor spectral resolution. Noise-dominated spectra with 2 keV full width at half maximum (FWHM) are presented. The results of a Monte Carlo simulation of spectral performance are compared to the measured spectra. The modeling enables one to characterize the traps in terms of cross section density products and trap release times.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measurement and modeling of the x-ray spectral response of bulk GaAs detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measurement and modeling of the x-ray spectral response of bulk GaAs detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement and modeling of the x-ray spectral response of bulk GaAs detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1142427

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.