Other
Scientific paper
Jun 2011
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2011mss..confemi10m&link_type=abstract
"International Symposium On Molecular Spectroscopy, 66th Meeting, Held 20-24 June, 2011 at Ohio State University. http://molspec
Other
Radicals And Ions
Scientific paper
Challenges to studying gas phase ions include the dilute analyte, Doppler line broadening, and a lack of ion/neutral discrimination. Techniques which provide high sensitivity, sub-Doppler features, and some form of ion/neutral discrimination increase the ability to study gas phase ions. Recently our group has used noise immune cavity enhanced optical heterodyne velocity modulated spectroscopy (NICE-OHVMS) to help overcome each of these challenges.
Using NICE-OHMS to probe a velocity modulated positive column produces a distinctive line shape. The high optical power from and geometry of the cavity saturates optical transitions and allows sub-Doppler Lamb dips to be observed. Depending on sideband frequency (1 or 9 times the free spectral range) the sub-Doppler features are closer together or further apart. The sub-Doppler features can then be used to measure the line-centers with high (˜1 MHz) precision and accuracy using an optical frequency comb.
The Kramers-Kronig relations describe how the absorption and dispersion are related to one another and can be used to obtain the absorption from the dispersion (and vice-versa). Owing to the phase dependent absorption signal produced with heterodyne spectroscopy, both absorption and dispersion signals can be obtained simultaneously. Two RF mixers (one for absorption and one for dispersion), each driving its own lock-in amplifier, are used to obtain a signal for ions and excited neutrals.
We will report a comparison of the sensitivities of several absorbance techniques to study a nitrogenic velocity modulated positive column including: direct absorption, cavity enhanced velocity modulation, heterodyne spectroscopy and NICE-OHMS, and show how the signal-to-noise ratio is increased by using NICE-OHMS.
Future plans for this technique include using a high power cw-OPO in the mid-IR to perform high precision vibrational spectroscopy of ions such as CH_5^+.
McCall Benjamin J.
Mills Rew
Porambo Michael
Siller Brian
No associations
LandOfFree
Lineshape and Sensitivity of Spectroscopic Signals of N_2^+ in a Positive Column Collected Using Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Lineshape and Sensitivity of Spectroscopic Signals of N_2^+ in a Positive Column Collected Using Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Lineshape and Sensitivity of Spectroscopic Signals of N_2^+ in a Positive Column Collected Using Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-999788