Life Test Results for Water Heat Pipes Operating at 200 °C to 300 °C

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Heat Engines, Heat Pumps, Heat Pipes, Servo And Control Equipment, Robots, Heat Flow In Multiphase Systems, Other Topics In Heat Transfer, Spaceborne And Space Research Instruments, Apparatus, And Components

Scientific paper

For lunar or planetary bases to be viable, a robust electric generating system will be required for powering the habitat. Water heat pipes offer an attractive solution for lunar base heat rejection, and would serve as a qualification for them on other long duration missions. Successful operation near the upper end of water operating range is a requirement for the application. Results are reported for life tests on water heat pipes that were operated at various temperatures between 200 °C and 300 °C. Tests were conducted on twenty three gravity-assisted water heat pipes. Eleven titanium/water heat pipes and ten Monel/water heat pipes were tested at temperatures above 200 °C. Two cupronickel heat pipes were also assembled and tested. Titanium alloys tested included CP-2 titanium, as well as two beta-titanium alloys, namely 15-3 and Nitinol alloys. Some of the titanium alloy life tests used wicks fabricated from CP-2 titanium screen or porous felt. Monel alloys tested included 400 and K-500 alloys. Some of the Monel heat pipes contained copper/nickel wicks that were fabricated by brazing nickel-plated copper felt metal wicks. Although most of the envelope/material combinations exhibit favorable results at 200 °C, some of the combinations failed at higher temperatures. Causes of failure included stress-creep of envelopes and corrosion at axial or end cap welds. This information represents a significant advance in selection of materials for 200 °C to 300 °C water heat pipes. Life testing work is being continued.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Life Test Results for Water Heat Pipes Operating at 200 °C to 300 °C does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Life Test Results for Water Heat Pipes Operating at 200 °C to 300 °C, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Life Test Results for Water Heat Pipes Operating at 200 °C to 300 °C will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1592087

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.