Statistics – Applications
Scientific paper
Jan 2004
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2004spie.5167..134l&link_type=abstract
Focal Plane Arrays for Space Telescopes. Edited by Grycewicz, Thomas J.; McCreight, Craig R. Proceedings of the SPIE, Volume 51
Statistics
Applications
2
Scientific paper
The demand for large-format NIR arrays has grown for both ground-based and space-based applications. These arrays are required for maintaining high resolution over very large fields of view for survey work. We describe results of the development of a new 2048 x 2048 HgCdTe/CdZnTe array with 20-micron pixels that responds with high quantum efficiency over the wavelength range 0.85 to 2.5 microns. With a single-layer anti-reflection (AR) coating, the responsive quantum efficiency is expected to be greater than 85% from 0.9 micron to 2.4 microns. The modular package for this array, dubbed the VIRGO array, allows three-side butting to form large mosaic arrays of 4K x 2nK format. The VIRGO readout integrated circuit (ROIC) utilizes a Source Follower per Detector (SFD) input circuit with a well capacity of about 2 x 105 electrons and with a read noise of less than 20 e-rms with off-chip Correlated Double Sampling (CDS). Other features of the VIRGO array include 4 or 16 outputs (programmable), and a frame rate of up to 1.5 Hz in 16-output mode. Power dissipation is about 7 mW at a 1 Hz frame rate. Reset modes include both global reset and reset by row (ripple mode). Reference pixels are built-in to the output data stream. The first major application of the VIRGO array will be for VISTA, the United Kingdom"s Visible and Infrared Survey Telescope for Astronomy. The VISTA FPA will operate near 80K. Dark current is less than 0.1e-/sec at 80K. The cutoff wavelength of the HgCdTe detector can be adjusted for other applications. Space applications might include SNAP, the Supernova/Acceleration Probe, which requires a shorter detector cutoff wavelength of about 1.7 microns. For applications which require both visible and NIR response, the detector CdZnTe substrate can be removed after hybridization, allowing the thinned detector to respond to visible wavelengths as short as 0.4 microns.
Ando Ken J.
Gulbransen David J.
Hoffman Alan W.
Holcombe Roger S.
Love Peter J.
No associations
LandOfFree
Large-format 0.85- and 2.5-μm HgCdTe detector arrays for low-background applications does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Large-format 0.85- and 2.5-μm HgCdTe detector arrays for low-background applications, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Large-format 0.85- and 2.5-μm HgCdTe detector arrays for low-background applications will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-828805