Laboratory test data on the stability of the STIS MAMAs

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Signal To Noise Ratios, Hubble Space Telescope, Multi-Anode Microchannel Arrays, Data Acquisition, Stability, Imaging Spectrometers, Radiation Detectors, Thermal Environments, Data Processing, Sensitivity

Scientific paper

STIS has two MAMA detectors systems with distinctly different tube configurations. The first (designated BAND 1) has an opaque CsI photocathode deposited on the microchannel plate (MCP) providing wavelength coverage from 1150A to 1700A. The other MAMA (designated BAND 2) has a semitransparent CS2Te photocathode deposited on the faceplate in close proximity to the input of the MCP. It covers the 1650A to 3100A bandpass and serves as a backup for the short wavelength detector. Laboratory test data indicate that both of these detectors have good sensitivity, have good uniformity and provide stable response, making each capable of collecting data with a signal-to-noise ratio in excess of 100 per Space Telescope Imaging Spectrograph (STIS) optical resolution element. Over a multiyear development effort, a substantial body of laboratory test data (more than 6 GBytes spanning more than 6 years of collection) has accumulated on more than a dozen fabricated tubes. These tests even included a few destructive evaluations to examine the limitations and operating life. In addition, analyses where conducted regarding impact caused by the specified electronic tolerances and expected changes in the Hubble Space Telescope (HST) thermal environment. Perhaps the simplest test of stability is to collect a sequence of images, each with a uniform illumination, and use these individual "flat fields" to remove the pixel-to-pixel sensitivity in the other flat fields. These sequences typically spanned 3-5 weeks of time. The detectors are very stable, allowing the pixel-to-pixel sensitivity to be removed with good precision. The STIS specification for stability is 1% (sufficient for data with a S/N = 100) over a 1 week period and 2% over 30 days. All Engineering Model Units as well as Flight Detectors tested exceeded this specification.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Laboratory test data on the stability of the STIS MAMAs does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Laboratory test data on the stability of the STIS MAMAs, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Laboratory test data on the stability of the STIS MAMAs will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1788328

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.