Laboratory performance of the Keck Interferometer nulling beam combiner

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

3

Nulling, Interferometry, Mid-Infrared

Scientific paper

Now that regular visibility squared measurements are routinely achieved, mid-infrared nulling is the next observing mode to be implemented on the Keck Interferometer (KI). This mode's main objective is the characterization of exo-zodiacal dust disks around nearby main sequence stars (Kuchner & Serabyn, 2003) in support of the TPF space mission. Keck Nuller also shares numerous characteristics with an interferometric TPF, and will then serve as a technical precursor for this mission. We report here the results obtained in the laboratory with the KI mid-IR nulling beam combiner, which is based on a dual polarization Modified Mach Zender (MMZ) combiner (Serabyn & Colavita, 2001), and dispersion compensation and achromatic nulling through zinc-selenide (ZnSe) dielectric plates (Koresko et al., 2002). Best broad-band dual polarization transient rejection levels obtained so far on thermal sources range from 7500:1 over a 29% bandwidth (FWHM from 9.20 to 12.35 microns) to 17000:1 with an 18% bandwidth (FWHM from 9.70 to 11.65 microns). These rejections are basically one order of magnitude better than the limit set by the stellar finite angular size, which is about 1000:1 at 10 microns for a 1 mas diameter star observed with KI 80m baseline. These results then validate the optical concept chosen for the nulling back-end, which now needs to be properly integrated with the mid-IR nulling camera and the KI beam train.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Laboratory performance of the Keck Interferometer nulling beam combiner does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Laboratory performance of the Keck Interferometer nulling beam combiner, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Laboratory performance of the Keck Interferometer nulling beam combiner will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-918040

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.