Laboratory calibration of x-ray transmission diffraction gratings

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

The 336 individual grating elements making up the High-Energy Transmission Grating (HETG) will be verified and calibrated in laboratory facilities at MIT as they are fabricated. A high instrument resolving power of order E/(Delta) E approximately equals 1000 requires an overall period uniformity of better than 250 ppm. To extract the maximum astrophysical information the diffraction efficiency of the HETG will be calibrated to the 1% level (1(sigma) ). Grating element period variations are measured and mapped in the Laser Reflection facility. Collimated HeCd (3250- angstrom) or HeNe (6328-angstrom) laser light is diffracted by the samples and measured. A per-point measurement noise of below 5 ppm rms and an overall period repeatability of 40 ppm rms have been achieved. X-ray diffraction efficiency in the 0.4 to 10 keV range is calibrated in the X-ray Grating Evaluation Facility (X- GEF). The facility combines a 17 meter vacuum beam line, a multi- anode X-ray source with monitor counter, a piezo-deformed 1D Ir coated focussing optic, a single-pixel solid state detector, and a 2D imaging proportional counter. The facility operation is under computer control and test procedures, instrumentation parameters, and acquired data are managed with a database. The system uses synchrotron-calibrated reference gratings as efficiency transfer standards. Detailed characterization and modeling of the X-GEF components and test/analysis procedures are being carried out to optimize the quality of the HETG calibration.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Laboratory calibration of x-ray transmission diffraction gratings does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Laboratory calibration of x-ray transmission diffraction gratings, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Laboratory calibration of x-ray transmission diffraction gratings will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1713439

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.