We present the results of recent work we have finished in the Operations Detector Lab on JWST near infrared detectors. This involves measuring the effects of temperature variations on the detectors and the decay time scales of persistence. The temperature results show that milli-Kelvin changes in the detector temperature lead to significant bias changes that will effect the sensitivity of any JWST instrument. Our persistence results show that it decays on many different time scales and is affected by the way the detector is reset.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

JWST Detector Characteristics Measured in the Operations Detector Lab at STScI does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with JWST Detector Characteristics Measured in the Operations Detector Lab at STScI, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and JWST Detector Characteristics Measured in the Operations Detector Lab at STScI will most certainly appreciate the feedback.