IXO x-ray mirrors based on slumped glass segments with reinforcing ribs: optical and mechanical design, image error budget, and optics unit integration process

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The International X-ray Observatory (IXO) is being studied as a joint mission by the NASA, ESA and JAXA space agencies. The main goals of the mission are large effective area (>3m2 at 1 keV) and a good angular resolution (<5 arcsec HEW at 1 keV). This paper reports on an activity ongoing in Europe, supported by ESA and led by the Brera Astronomical Observatory (Italy), aiming at providing an alternative method for the realization of the mirror unit assembly. This is based on the use of thin glass segments and an innovative assembly concept making use of glass reinforcing ribs that connect the facets to each-other. A fundamental challenge is the achievement with a hot slumping technique of the required surface accuracy on the glass segments. A key point of the approach is represented by the alignment of the mirror segments and co-alignment of the mirror pairs assembled together. In this paper we present the mirror assembly conceptual design, starting from the design of the optical unit, the error budgets contributing to the image degradation and the performance analysis to assess error sensitivities. Furthermore the related integration concept and the preliminary results obtained are presented.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

IXO x-ray mirrors based on slumped glass segments with reinforcing ribs: optical and mechanical design, image error budget, and optics unit integration process does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with IXO x-ray mirrors based on slumped glass segments with reinforcing ribs: optical and mechanical design, image error budget, and optics unit integration process, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and IXO x-ray mirrors based on slumped glass segments with reinforcing ribs: optical and mechanical design, image error budget, and optics unit integration process will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1375519

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.