Image degradation due to assembly and alignment errors in conical foil x-ray telescopes

Statistics – Methodology

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The technology to fabricate and assemble many concentric, nested conical foil x-ray telescopes for high-throughput, moderate-resolution, spectroscopic applications promises to be a cost-effective alternative to the grinding and polishing of conventional grazing incidence Wolter Type I telescopes. The three fundamental mechanisms that degrade achievable resolution for any imaging system are diffraction, geometrical aberrations (due to residual design errors, surface figure errors, and alignment errors), and scattering due to residual optical surface irregularities. A detailed parametric analysis of the image degradation due to each of these mechanisms is presented, with particular emphasis on the assembly and alignment errors for these tightly nested conical foil x-ray telescopes. A detailed error budget tree is then developed from which assembly and alignment tolerances can be derived. This error budget tree allows systems engineering trade-offs between foil surface tolerances, assembly and alignment tolerances, and the intrinsic resolution due to diffraction and residual design errors (the conical approximation to the ideal paraboloidal and hyperboloidal surface figure). Although the Danish Space Research Institute's XSPECT conical foil x-ray telescope design parameters were used in this study, the methodology developed is applicable to any nested array of grazing incidence x-ray telescopes.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Image degradation due to assembly and alignment errors in conical foil x-ray telescopes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Image degradation due to assembly and alignment errors in conical foil x-ray telescopes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Image degradation due to assembly and alignment errors in conical foil x-ray telescopes will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1139520

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.