Other
Scientific paper
Dec 2005
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2005spie.6024..507l&link_type=abstract
ICO20: Optical Devices and Instruments. Edited by Wyant, James C.; Zhang, X. J. Proceedings of the SPIE, Volume 6024, pp. 50
Other
Scientific paper
Structural and hygrothermal analysis for a composite tube is carried out in this study, that provides critical parameters for the design of a highly dimensionally stable space telescope. Carpet plots for laminate effective engineering constants are generated and used for the best tube lay-ups with high elastic modulus and highly insensitive to thermal and moisture expansion, which is essential for maintaining optical alignment of opto-mechanical system under random force applied during a launch campaign and orbital thermal load. Despace in the longitudinal direction under hygrothermal load of the tubes constructed with the selected lay-ups is calculated for the validation of lay-up designs on the dimensional stability. Dynamic analysis is also carried out to feature the resonant behaviour. A zig-zag triangular element accurately representing through thickness stress variations for laminated structures is developed in this study and incorporated into the structural and hygrothermal analysis.
No associations
LandOfFree
Hygrothermal design of high stability telescope structure does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Hygrothermal design of high stability telescope structure, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Hygrothermal design of high stability telescope structure will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1461154