Hydrothermal system beneath Mt. Fuji volcano inferred from magnetotellurics and electric self-potential

Computer Science – Sound

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

9

Scientific paper

Wideband magnetotelluric (MT) soundings were carried out on Mt. Fuji volcano along a northeast to southwest axis. It was found by two-dimensional inversion using the highest quality data (in the frequency range 1 300 Hz) that a good conductor (resistivity of approximately a few ohm m) was located beneath the summit with a lateral extent of approximately 4 km. It begins approximately 1 km below the ground surface; however, its depth cannot be resolved. In our previous study, an intense positive self-potential (SP) anomaly (approximately 2000 mV), was found around a summit crater having a diameter of approximately 3 km. We interpreted the presence of the good conductor and positive SP anomaly as a strong indication of an active hydrothermal system. Subsequently, we searched for conduction current sources to explain the SP distribution on the surface by using the resistivity structure determined by the MT inversion. The results obtained were that a positive conduction current source of the order of 1000 A should be located at the top of the conductor. From these results, we deduced that the conductor represents a hydrothermal system in which single-phase (liquid) convection is taking place. Since the resistivity at a distance from the good conductor can be explained by the effect of cold groundwater, the hydrothermal system does not seem to extend throughout the entire body of the volcano, but seems to be confined to the area beneath the summit crater. Finally, an estimate of the order of magnitude of the subsurface hydrothermal flow was performed using a relation between the fluid volume flux and electric current density in the capillary model. The result suggested that there exists fairly low permeability within the shallow part of Mt. Fuji. We speculate that the low permeability in the volcano has a correlation with the confinement of the hydrothermal system and quiescence of volcanic activities, such as low seismicity, no gas emanations, and no natural hot springs.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Hydrothermal system beneath Mt. Fuji volcano inferred from magnetotellurics and electric self-potential does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Hydrothermal system beneath Mt. Fuji volcano inferred from magnetotellurics and electric self-potential, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Hydrothermal system beneath Mt. Fuji volcano inferred from magnetotellurics and electric self-potential will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-872849

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.