Time-resolved radiographic imaging of low density, solid spherical surrogate targets has been used to provide a time-dependent measurement of drive pressure symmetry in cylindrical hohlraums on both the Nova and Omega lasers. The experiments replace the usual capsule at the center of a gold hohlraum with a sphere of SiO2 foam (ρ=0.3 g/cm3). The laser generates an x-ray drive inside the hohlraum which does not produce perfectly symmetric drive pressure on a spherical target, giving rise to a distorted shock traveling radially inward. The rarefaction behind the shock generated in this sphere produces a rapid rise in x-ray transmission which is easily detectable experimentally by radiography. The position of this feature may be determined to within a few microns in our experimental setup using a gated x-ray pinhole camera. Time-dependent control of drive symmetry in a hohlraum requires the ability to adjust the laser power as a function of both time and position along the hohlraum axis. We have implemented this control on the Omega laser by delaying sets of beams (``beam staggering'') and on the Nova laser (``beam phasing'') by delivering two independent pulse shapes on inner and outer halves of the Nova beams. The improvement in P2 pressure symmetry with this control as measured with the foam ball technique was found to be as much as a factor of 3, compared with deliberately mistuned drives. On the National Ignition Facility (NIF), we expect to use this technique as part of the effort to tune drive symmetry to achieve higher gain. We present results from these experiments from both facilities and comparisons with LASNEX simulations. In addition, we discuss the application of the foam ball technique to NIF targets.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Hohlraum symmetry measurements with surrogate solid targets (invited) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Hohlraum symmetry measurements with surrogate solid targets (invited), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Hohlraum symmetry measurements with surrogate solid targets (invited) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1277046

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.