Highly sensitive large-area bolometers for scintillation studies below 100 mK (from near IR to soft x rays)

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

At very low temperature large area bolometers may show a better sensitivity than photomultipliers or semiconductor diodes, while allowing fluorescence measurements of cool targets with no window, no infrared background, good optical couplings and a flat response on a large absorption bandpass. The optical absorber of these composite bolometers can be matched to the desired bandpass. Here we present the design, the performances and calibration tests of a new generation of large area (5 cm2) optical bolometers with a pure germanium disk absorbing on a wide spectral band from near-IR to X-rays. Performances obtained at 25 mK are very promising : Noise Equivalent Power as low as 4x10-17 W/√Hz in the photometry mode, energy threshold about 50 eV in the single photon detection mode, and time constant τ~3 ms. These detectors of low mass (0.25 g) have been recently successfully used for detecting the fluorescence emitted by much more massive bolometers, having for example a BGO (92 g), or a CaWO4 (54 g) target. The simultaneous detection of heat and light in these <> permits the identification of each event in the massive target (α decay, or γ cosmic ray interaction, neutron recoil…). Thanks to the consecutive excellent subtraction of the radioactive and cosmic rays background, it is a powerful tool developed by several groups for fundamental research : study of very rare decays of atoms, measurement of internal very low radioactivity content in single crystals, direct detection of dark matter recoils in massive fluorescence targets, detection of solar neutrino fluorescence events in liquid 4He…Recently obtained results which support this new promising field are reminded: the first detection of the rare alpha decay of 209Bi, and new scintillation data on Al2O3 (sapphire), LiF or TeO2 at 20mK. We discuss the ultimate performances at 12 mK of the optical bolometers as a function of their area, as well as the optimisation of their absorbing part to the desired bandpass, and finally, we estimate achievable improvements of our current technology.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Highly sensitive large-area bolometers for scintillation studies below 100 mK (from near IR to soft x rays) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Highly sensitive large-area bolometers for scintillation studies below 100 mK (from near IR to soft x rays), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Highly sensitive large-area bolometers for scintillation studies below 100 mK (from near IR to soft x rays) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1489531

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.