A high sensitivity triple-coupled quantum well infrared photodetector (TC-QWIP) based on high strain InGaAs/AlGaAs/InGaAs material system has been demonstrated. It consists of a high strain Si-doped In(subscript 0.25)Ga(subscript 0.75)As quantum well and two undoped thin Al(subscript 0.11)Ga(subscript 0.89)As/In(subscript 0.12)Ga(subscript 0.88)As quantum wells (QWs) separated by a thick Al(subscript 0.11)Ga(subscript 0.89)As barrier layer. We also investigate the performance dependence of this QWIP with two different numbers of quantum well periods (5- and 10-period). Two response peaks at 9.5 micrometer and 7 micrometer were observed under different negative bias conditions, which are attributed to the transitions from the ground state to the second excited states and the continuum states, respectively. Spectral responsivities of 2.77 A/W and 1.55 A/W and the BLIP detectivities of 2.24 X 10(superscript 10) cm-Hz(superscript 1/2)/W and 1.68 X 10(superscript 10) cm-Hz(superscript 1/2)/W were obtained at V(subscript b) equals -3 V and (lambda) (subscript p) equals 9.6 micrometer with 45 degree facet illumination and normal incidence illumination, respectively, for the 5-period device. As to the 10-period device, spectral responsivities of 2.7 A/W and 1.05 A/W and the BLIP detectivities of 2.21 X 10(superscript 10) cm-Hz(superscript 1/2)/W and 1.38 X 10(superscript 10) cm-Hz(superscript 1/2)/W were obtained at V(subscript b) equals -5 V and (lambda) (subscript p) equals 9.6 micrometer with 45 degree facet illumination and normal incidence illumination, respectively, for this device. This represents the highest normal incidence response ever reported for a QWIP operating at 9.6 micrometer peak wavelength. Based on the responsivity and detectivity data the minimum detectable photon flux for this new device is found to be 1.08 X 10(superscript 11) and 1.09 X 10(superscript 11) cm(superscript -2)s(superscript -1) for the 5-period and 10- period devices, respectively, at (lambda) (subscript p) equals 9.6 micrometer, bandwidth equals 1 micrometer, and FOV equals 180 degrees. Thus, the HS-TC-QWIP reported here is capable for lower background IR imaging array applications.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

High-sensitivity normal incidence triple-coupled quantum well IR photodetector for lower-background infrared detection does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with High-sensitivity normal incidence triple-coupled quantum well IR photodetector for lower-background infrared detection, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High-sensitivity normal incidence triple-coupled quantum well IR photodetector for lower-background infrared detection will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1177118

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.