High dynamic range imaging with a single-mode pupil remapping system : a self-calibration algorithm for redundant interferometric arrays

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

11 pages, 7 figures. Accepted for publication in MNRAS

Scientific paper

10.1111/j.1365-2966.2006.11198.x

The correction of the influence of phase corrugation in the pupil plane is a fundamental issue in achieving high dynamic range imaging. In this paper, we investigate an instrumental setup which consists in applying interferometric techniques on a single telescope, by filtering and dividing the pupil with an array of single-mode fibers. We developed a new algorithm, which makes use of the fact that we have a redundant interferometric array, to completely disentangle the astronomical object from the atmospheric perturbations (phase and scintillation). This self-calibrating algorithm can also be applied to any - diluted or not - redundant interferometric setup. On an 8 meter telescope observing at a wavelength of 630 nm, our simulations show that a single mode pupil remapping system could achieve, at a few resolution elements from the central star, a raw dynamic range up to 10^6; depending on the brightness of the source. The self calibration algorithm proved to be very efficient, allowing image reconstruction of faint sources (mag = 15) even though the signal-to-noise ratio of individual spatial frequencies are of the order of 0.1. We finally note that the instrument could be more sensitive by combining this setup with an adaptive optics system. The dynamic range would however be limited by the noise of the small, high frequency, displacements of the deformable mirror.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

High dynamic range imaging with a single-mode pupil remapping system : a self-calibration algorithm for redundant interferometric arrays does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with High dynamic range imaging with a single-mode pupil remapping system : a self-calibration algorithm for redundant interferometric arrays, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High dynamic range imaging with a single-mode pupil remapping system : a self-calibration algorithm for redundant interferometric arrays will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-243797

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.