Generation of harmonic frequencies and their effects in present day ICRF systems

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Plasma Heating By Particle Beams, Theory, Design, And Computerized Simulation

Scientific paper

The whole TEXTOR-94 ICRF system [1,2] circuit has been analyzed, partially modelled and studied at the fundamental operating frequency and, more important, at harmonic frequencies thereof. It has been found that without appropriate measures, present day systems and especially the TEXTOR ICRF system are prone to spurious generation of power at the second harmonic frequency. This leads either to erroneous activation of the reflected power safety protection or to highly increased (in some cases doubled) voltages in the transmission lines and antennas. As the voltage standing waves at the second harmonic displace the total voltage maxima in the transmission lines and antennas, this also explains why arcs are not always found at the expected voltage maxima for the fundamental frequency. The model is also able to give additional explanations why the ASDEX-Upgrade ICRF system has dramatically improved its power handling capabilities after the introduction of the ``3dB coupler reflection compensation scheme'' [3,4]. The output of one of the TEXTOR transmitters has been fitted with a quarter wave length shorted stub which has no effect on the operation at the fundamental frequency but which effectively shorts out the second harmonic. It has to be noted that eg. the Tore Supra RDL [5] antennas are fitted with such a stub in the feeding transmission line whose function is to enter cooling water into the transmission line system. Hence, this could be the explanation of the apparent higher than average power handling capabilities of the TS antenna system. Experimental results clearly indicate a much improved operational power handling capability on plasma and an increased voltage stand-off when conditioning this antenna pair on vacuum. Limits have yet to be explored but already remarkable is the fact that since the installation of the quarter wavelength stub the reflected power safety system has been activated only once and furthermore so in poorly matched conditions.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Generation of harmonic frequencies and their effects in present day ICRF systems does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Generation of harmonic frequencies and their effects in present day ICRF systems, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Generation of harmonic frequencies and their effects in present day ICRF systems will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1768234

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.