Other
Scientific paper
Jul 2002
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2002aipc..623..399c&link_type=abstract
AIP Conference Proceedings, vol. 623, iss. no. 1, p. 399-402
Other
Cosmic Ray Showers, Photomultiplier Tubes, Radiation Detectors, Scintillation Counters, Telescopes, Neutrino, Muon, Pion, And Other Elementary Particle Detectors, Cosmic Ray Detectors, Scintillation Detectors
Scientific paper
We describe the operation of an Extensive Air Shower Array located at the campus of the FCFM-BUAP. The array consists of 8 liquid scintillation detectors with a surface of 1 m2 each and a detector spacing of 20 m in a square grid. The array was designed to measure the energy and arrival direction of primary particles that generate extensive air showers (EAS) in the region of 1013 eV - 1016 eV. The angular distribution measured with this array, Cos8(Theta) xSin(Theta), agrees very well with the literature. We also present the measured energies of a number of vertical showers in the range of 5 x1012 eV to 5 x1013 eV.
Aguilar Silvestre
Cotzomi J.
Martinez Oscar
Moreno Esteban
Palma B.
No associations
LandOfFree
Extensive Air Shower Detector Array at the Universidad Autonoma de Puebla does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Extensive Air Shower Detector Array at the Universidad Autonoma de Puebla, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Extensive Air Shower Detector Array at the Universidad Autonoma de Puebla will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-959727