Estimating temperature and emissivity for infrared measurements using a PtSi Schottky-barrier infrared CCD image sensor

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A new analytical method to estimate temperature and emissivity for infrared measurements is described. There are four steps in the method. First, in calculating the output voltage, the dependence of temperature and emissivity of the object was evaluated. The result was the output voltage increased in proportion to the second power of the object temperature and the dependence of the emissivity was linear for the 250 K to 400 K temperature range. Second, in the fitting of these polynomial equations, the orders of six coefficients were also evaluated. Third, in measuring the output voltage of the standard imaging area, the unit transfer coefficient from digital unit (LSB) to voltage (V) was computed. Finally, an inversion problem for estimating temperature and emissivity of the object was proposed. We have developed a new kind of 3 approximately 5 micrometers band Schottky-barrier infrared CCD image sensor, which we call SCAT648, to verify the validity of the estimating method. The SCAT648 image sensor is composed of the different types of pixels. These pixels have different spectral responsivities and capabilities of measuring target temperature and target emissivity. Four standard temperature-controlled samples were imaged with the newly developed SCAT648 camera system. We estimate the error of the temperature and emissivity measurements to be a low +/- 0.5 K and +/- 5%, respectively.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Estimating temperature and emissivity for infrared measurements using a PtSi Schottky-barrier infrared CCD image sensor does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Estimating temperature and emissivity for infrared measurements using a PtSi Schottky-barrier infrared CCD image sensor, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Estimating temperature and emissivity for infrared measurements using a PtSi Schottky-barrier infrared CCD image sensor will most certainly appreciate the feedback.

Rate now

     