Computer Science
Scientific paper
Dec 1984
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1984opmep..51...18p&link_type=abstract
(Optiko-Mekhanicheskaia Promyshlennost', vol. 51, Dec. 1984, p. 18-20) Soviet Journal of Optical Technology (ISSN 0038-5514), vo
Computer Science
Instrument Errors, Telescopes, Displacement, Error Analysis, Focusing, Ray Tracing
Scientific paper
An expression is obtained for the dependence of the variation in the orientation of the aiming axis of a two-component telephoto lens of a telescope on the displacement (along the axis) of its focusing component when the latter is displaced at right angles to the aiming axis and the direction of motion of the focusing component is not parallel to the line joining the crosshairs of the telescope and the center of the lens itself.
No associations
LandOfFree
Error in the measurement of horizontal angles by an angle-measuring instrument due to a deviation of the aiming axis of the telescope during refocusing does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Error in the measurement of horizontal angles by an angle-measuring instrument due to a deviation of the aiming axis of the telescope during refocusing, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Error in the measurement of horizontal angles by an angle-measuring instrument due to a deviation of the aiming axis of the telescope during refocusing will most certainly appreciate the feedback.