Electron density diagnostic for hot plasmas in coronal regime by using B-like ions

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

15 pagess, 5 figures and 4 tables, accepted for publication on AJ

Scientific paper

10.1088/0004-6256/135/6/2291

Line ratio of $3d-2p$ transition lines in boron-like spectra of Si X, S XII, Ar XIV and Fe XXII has been investigated. Collisional-radiative model calculations reveal that the line ratio is sensitive to the electron density in ranges of $n_{\rm e}=4.0\times10^7-3.0\times10^{10}$ cm$^{-3}$, $4.0\times10^8-3.0\times10^{11}$ cm$^{-3}$, $3.0\times10^9-4.0\times10^{12}$ cm$^{-3}$ and $2.0\times10^{12}-3.0\times10^{15}$ cm$^{-3}$, respectively. This complements the K-shell diagnostics of helium-like ions. By comparison between the prediction and the measured values, effective electron densities in the electron beam ion trap (EBIT) plasmas performed by Lepson and collaborators at Lawrence Livermore EBIT, are estimated to be $n_{\rm e}=3.4^{+0.8}_{-0.6}\times10^{10}$ cm$^{-3}$ and $5.6^{+1.0}_{-1.1}\times10^{10}$ cm$^{-3}$ for sulphur and argon plasmas. In case of argon, a good agreement is shown with the actual electron density derived from N VI K-shell spectrum. We further explore the $3d-2p$ transition lines of Si X and S XII in the stellar coronal spectra measured with the Low Energy Transmission Grating Spectrometer combined with High Resolution Camera on board the {\it Chandra X-ray Observatory}. The constrained electron densities show a good agreement with the those determined from C V and O VII K-shell spectra.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Electron density diagnostic for hot plasmas in coronal regime by using B-like ions does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Electron density diagnostic for hot plasmas in coronal regime by using B-like ions, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Electron density diagnostic for hot plasmas in coronal regime by using B-like ions will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-246523

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.