Discarded low energy particles in extensive air shower simulations: Effect on the shower Energy Deposit

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

15 pages, 7 figures, submited to Journal of physics G

Scientific paper

The simulation of particle cascades initiated in the atmosphere by ultra high energy cosmic ray particles involves the generation and propagation of a huge amount of particles. As it is unpractical to follow every particle to its end, particles below a certain energy ($E_{Cut}$) are discarded from the simulation. In this article we study in detail the influence that this cut has on the total energy deposited in the atmosphere by the particle cascade in AIRES simulations. The energy deposit is directly related to the emission of fluorescence light and is critical for the accurate simulation of shower signals in fluorescence detectors. Not correcting for the discarded particles introduces a bias on several shower observables related to the energy deposit that can range from 3 to 30% or more depending on the $E_{Cut}$ value used. A prescription for the correct treatment of these particles is proposed, and the resulting corrections to the total energy deposit are addressed, including a new universal parametrization of the mean energy deposit per particle. The low energy cut is introduced in the simulations to reduce the required CPU time per shower at the expense of simulation accuracy. We find that a 0.4 MeV cut for electrons and 0.9 MeV cut for gammas is an adequate compromise, and that the proposed prescription is capablable of removing the bias introduced by this cut. The prescription is independent of the energy cut value and can be used to correct and compare simulations made with different energy cuts.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Discarded low energy particles in extensive air shower simulations: Effect on the shower Energy Deposit does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Discarded low energy particles in extensive air shower simulations: Effect on the shower Energy Deposit, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Discarded low energy particles in extensive air shower simulations: Effect on the shower Energy Deposit will most certainly appreciate the feedback.