Differential Emission Measure: Forward Folding vs. Automatic Inversion

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

When attempting to compare models and observations of the solar corona, an accurate determination of the multi-thermal distribution of the plasma along the line of sight is clearly superior to the single value of temperature obtained from an isothermal approximation. But methods of determining the Differential Emission Measure (DEM) are fraught with pitfalls. Forward Folding is subjective and time consuming: an initial model DEM curve is convolved with the emissivity function of the spectral lines. This produces a set of predicted intensities that are compared with the observed values. The emission measure distribution is then adjusted manually to improve the agreement between the observed and predicted intensities while keeping the curve as smooth a function of temperature as possible. The process is repeated until, ideally, the predicted and observed intensities agree to within approximately 1-2 sigma. Automatic inversion techniques are mathematically ill posed, so small changed in the observed spectral line intensities can result in large differences in the DEM solution. The programs are too often used as a 'black box,' and the physical relevance of these solutions has (rightfully so) been questioned. We attempt to minimize these pitfalls by comparing and contrasting the temperature distributions obtained from forward folding with two different automatic inversion techniques. We used three different data sets: (1) SERTS iron line intensities of an active region from the 1993 Aug 17 rocket flight; (2) Solar Maximum Mission Flat Crystal Spectrometer data for a flare on 1980 Aug 30; and (3) XSST spectral data of a flare from the 1982 Jul 13 rocket flight. Solar physics research at the University of Memphis is supported by NASA grant NAG5-9783.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Differential Emission Measure: Forward Folding vs. Automatic Inversion does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Differential Emission Measure: Forward Folding vs. Automatic Inversion, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Differential Emission Measure: Forward Folding vs. Automatic Inversion will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1716943

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.