International Amateur-Professional Photoelectric Photometry Communication, No. 14, p.19
Other
Scientific paper
Determining accurately both extinction and transformation coefficients is of great importance when preparing an observatory to do photoelectric photometry. The authors have done this for the SSP-3 photometer at the Argo Navis Observatory. It is not intended that these extinction or transformation coefficients be used by other observatories, but only that the method may be used by others to determine these coefficients for their own equipment and observatory.
Persha G.
Sanders W. H.
No associations
LandOfFree
Determination of Extinction and Transformation Coefficients in the BVRI Bands Using SSP-3 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Determination of Extinction and Transformation Coefficients in the BVRI Bands Using SSP-3, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Determination of Extinction and Transformation Coefficients in the BVRI Bands Using SSP-3 will most certainly appreciate the feedback.