Detection of Extended HI Absorption in Abell 2597

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We report the detection of extended HI in absorption against the bright radio source PKS 2322--123 in the cD galaxy in the `cooling flow' cluster A2597. We used the VLA in the A configuration with 2.3times 1.5 arcsec spatial resolution and at two velocity resolutions centered at the systemic velocity of the cD (z=0.082) (1) 48 km/s velocity resolution over a range of 1304 km/s and (2) 1.5 km/s over a range of 524 km/s. The HI profile has a FWHM of ~ 410 km/s and a peak optical depth of tau =~ 0.0056 and is centered near the systemic velocity of the cD. We derive a lower limit to the covering factor of the HI clouds in front of the radio source of c_f > 0.006. We have sufficient signal-to-noise to detect the HI over the bright inner parts of the radio source with extent ~ 4" (5.6 kpc). The estimated mass in the HI is about an order of magnitude larger than that inferred in the Hα emitting filaments (over the same region) suggesting that the nebula is photon bounded rather than matter bounded. The (1) broad velocity width of the HI (which is similar to the Hα ), (2) the extended nature of the HI, and (3) the result that the nebula is photon bounded are all consistent with the hypothesis that the Hα filaments are the ionized skins of a population of HI clouds. If this is the case then we can combine the optically derived volume filling factor with the radio derived covering factor to place limits on the cloud radius of 0.02 < rcl < 4 pc. We also detect a narrower (FWHM ~ 220 km/s) deeper (tau =~ 0.019) spatially unresolved (< 2 kpc) component towards the nucleus only which is redshifted by about 300 km/s and thus represents material infalling towards the nucleus. This gas is kinematically and spatially distinct from the extended HI and might have been acquired from a merger/interaction. We discuss these results in the context of current models for the optical and x-ray emission from `cooling flow' clusters.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Detection of Extended HI Absorption in Abell 2597 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Detection of Extended HI Absorption in Abell 2597, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Detection of Extended HI Absorption in Abell 2597 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-779126

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.