Detection of amino acetonitrile in Sgr B2(N)

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

30 pages, 8 figures, accepted for publication in Astronomy and Astrophysics (A&A). Version 2: minor changes (one author affili

Scientific paper

10.1051/0004-6361:20079203

Amino acids are building blocks of proteins and therefore key ingredients for the origin of life. The simplest amino acid, glycine, has long been searched for in the interstellar medium but has not been unambiguously detected so far. Since the search for glycine has turned out to be extremely difficult, we aimed at detecting a chemically related species (possibly a direct precursor), amino acetonitrile. With the IRAM 30m telescope we carried out a complete line survey of the hot core regions Sgr B2(N) and (M) in the 3 mm range, plus partial surveys at 2 and 1.3 mm. We analyzed our 30m line survey in the LTE approximation and modeled the emission of all known molecules simultaneously. We identified spectral features at the frequencies predicted for amino acetonitrile lines having intensities compatible with a unique rotation temperature. We also used the VLA to look for cold, extended emission from amino acetonitrile. We detected amino acetonitrile in Sgr B2(N) in our 30m telescope line survey and conducted confirmatory observations of selected lines with the IRAM PdB and the ATCA interferometers. The emission arises from a known hot core, the Large Molecule Heimat, and is compact with a source diameter of 2 arcsec (0.08 pc). We derived a column density of 2.8e16 cm-2, a temperature of 100 K, and a linewidth of 7 km s-1. Based on the simultaneously observed continuum emission, we calculated a density of 1.7e8 cm-3, a mass of 2340 Msun, and an amino acetonitrile fractional abundance of 2.2e-9. The high abundance and temperature may indicate that amino acetonitrile is formed by grain surface chemistry. We did not detect any hot, compact amino acetonitrile emission toward Sgr B2(M) or any cold, extended emission toward Sgr B2, with column-density upper limits of 6e15 and 3e12-14 cm-2, respectively. (abridged)

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Detection of amino acetonitrile in Sgr B2(N) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Detection of amino acetonitrile in Sgr B2(N), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Detection of amino acetonitrile in Sgr B2(N) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-594465

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.